Electrical connection
• Make sure that the rated voltage and type of power
on the rating plate agree with the voltage and the
power of the local power supply.
• This appliance is supplied with a mains cable and a
plug.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug
after the installation.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• There is a risk of fire when the appliance is in
connection with an extension cable, an adapter or a
multiple connection. Make sure that the ground
connection agrees with the standards and
regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable
connected at all times.
Connection cable
To replace the connection cable use only the special
cable or its equivalent. The cable type is: H05V2V2-
FT90.
Make sure that the cable section is applicable to the
voltage and the working temperature. The yellow /
green earth wire must be approximately 2 cm longer
than the brown (or black) phase wire.
Assembly
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
min. 100 mm
30 mm
480 mm
4.
25